Switched Mode Power Supplies (SMPS)
Power Electronics
Unit of Measure
Items |
![]() SPB-240-48 100 to 240 Volt (V) Alternating Current (AC) Input Voltage and 240 Watt (W) Output Power Switched Mode Power Supply (SMPS) List Price $164.95
|
![]() SPB-240-24 100 to 240 Volt (V) Alternating Current (AC) Input Voltage and 240 Watt (W) Output Power Switched Mode Power Supply (SMPS) List Price $164.95
|
![]() SPB-240-12 100 to 240 Volt (V) Alternating Current (AC) Input Voltage and 240 Watt (W) Output Power Switched Mode Power Supply (SMPS) List Price $164.95
|
![]() SPB-120-48 100 to 240 Volt (V) Alternating Current (AC) Input Voltage and 120 Watt (W) Output Power Switched Mode Power Supply (SMPS) List Price $97.95
|
![]() SPB-120-24 100 to 240 Volt (V) Alternating Current (AC) Input Voltage and 120 Watt (W) Output Power Switched Mode Power Supply (SMPS) List Price $97.95
|
|||||
Description | N/A Power Supply, Din Rail mounting, Switching, 48 VDC output ,240 Watts, 5 Amp 100-240 VAC Input | N/A Power Supply, Din Rail mounting, Switching, 24 VDC output ,240 Watts, 10 Amp 100-240 VAC Input | N/A Power Supply, Din Rail mounting, Switching, 12 VDC output ,240 Watts, 20 Amp 100-240 VAC Input | N/A Power Supply, Din Rail mounting, Switching, 48 VDC output ,120 Watts, 2.5 Amp 100-240 VAC Input | N/A Power Supply, Din Rail mounting, Switching, 24 VDC output ,120 Watts, 5 Amp 100-240 VAC Input | |||||
Brands | N/A Autonics USA | |||||||||
Output Power | N/A 240 W | N/A 240 W | N/A 240 W | N/A 120 W | N/A 120 W | |||||
Alternating Current (AC) Input Voltage | N/A 100 to 240 V | |||||||||
Alternating Current (AC) Input Frequency | N/A | N/A 50 Hz60 Hz | N/A | N/A | N/A 50 Hz60 Hz | |||||
Alternating Current (AC) Permissible Voltage | N/A | N/A 85 to 264 V | N/A | N/A | N/A 85 to 264 V | |||||
Alternating Current (AC) Permissible Frequency | N/A | N/A 50 Hz60 Hz | N/A | N/A | N/A 50 Hz60 Hz | |||||
Direct Current (DC) Permissible Voltage | N/A | N/A 120 to 370 V | N/A | N/A | N/A 120 to 370 V | |||||
Mounting | N/A German Institute of Standardization (DIN) Rail | |||||||||
Protection | N/A | N/A Inrush Current Output Low-Voltage Indicate Output Short-Circuit Over-Current Over-Voltage Power Factor Correction Remote Control Terminal Cover | N/A | N/A | N/A Inrush Current Output Low-Voltage Indicate Output Short-Circuit Over-Current Over-Voltage Power Factor Correction Remote Control Terminal Cover | |||||
Approval | N/A | N/A European Conformity (CE) Underwriters Laboratory for Canada and United States (cULus) Listed | N/A | N/A | N/A European Conformity (CE) Underwriters Laboratory for Canada and United States (cULus) Listed | |||||
Input Frequency | N/A | N/A 50 Hz60 Hz | N/A | N/A | N/A 50 Hz60 Hz | |||||
Input Efficiency at 100 Volt (V) Alternating Voltage (AC) Voltage | N/A | N/A 0.89 % | N/A | N/A | N/A 0.85 % | |||||
Input Efficiency at 240 Volt (V) Alternating Voltage (AC) Voltage | N/A | N/A 0.92 % | N/A | N/A | N/A 0.88 % | |||||
Minimum Input Power Factor | N/A | N/A 0.9 % | N/A | N/A | N/A 0.9 % | |||||
Input Current Consumption at 100 Volt (V) Alternating Voltage (AC) Voltage | N/A | N/A 2.71 A | N/A | N/A | N/A 1.49 A | |||||
Input Current Consumption at 240 Volt (V) Alternating Voltage (AC) Voltage | N/A | N/A 1.12 A | N/A | N/A | N/A 0.61 A | |||||
Voltage Adjustment Range (±) | N/A | |||||||||
Maximum Voltage Adjustment Range (±) | N/A | N/A 0.5 % | N/A | N/A | N/A 5 % | |||||
Maximum Input Fluctuation Ratio (±) | N/A | N/A 1 % | N/A | N/A | N/A 0.5 % | |||||
Maximum Load Fluctuation Ratio (±) | N/A | N/A 1 % | N/A | N/A | N/A 1 % | |||||
Maximum Ripple and Ripple Noise | N/A | N/A 1 % | N/A | N/A | N/A 1 % | |||||
Protection Structure | N/A | N/A Ingress Protection (IP) 20 (International Electrotechnical Commission (IEC) Standard) | N/A | N/A | N/A Ingress Protection (IP) 20 (International Electrotechnical Commission (IEC) Standard) | |||||
Environment Ambient Temperature | N/A | N/A -10 to 50 ºC | N/A | N/A | N/A -10 to 50 ºC | |||||
Environment Storage Temperature | N/A | N/A -25 to 65 ºC | N/A | N/A | N/A -25 to 65 ºC | |||||
Maximum Surrounding Air Temperature | N/A | N/A 40 ºC | N/A | N/A | N/A 40 ºC | |||||
Environment Ambient Relative Humidity (RH) | N/A | N/A 25 to 85 % | N/A | N/A | N/A 25 to 85 % | |||||
Environment Storage Relative Humidity (RH) | N/A | N/A 25 to 90 % | N/A | N/A | N/A 25 to 90 % | |||||
Alternating Current (AC) Voltage | N/A | |||||||||
Contact Type | N/A | |||||||||
Input Efficiency | N/A | |||||||||
Minimum Input Efficiency | N/A | |||||||||
Maximum Input Current Consumption | N/A | |||||||||
Length | N/A | |||||||||
Width | N/A | |||||||||
Height | N/A | |||||||||
Direct Current (DC) Output Voltage | N/A 48 V | N/A 24 V | N/A 12 V | N/A 48 V | N/A 24 V | |||||
Output Current | N/A 5 A | N/A 10 A | N/A 20 A | N/A 2.5 A | N/A 5 A | |||||
Output Capacity | N/A | |||||||||
Maximum Ripple | N/A | |||||||||
Maximum Voltage Fluctuation Ratio at 85 to 264 Volt (V) Alternating Current (AC) Voltage and 100 Percent (%) Load | N/A | |||||||||
Contact Block Type | N/A | |||||||||
Light Emitting Diode (LED) Block Alternating Current (AC) Voltage | N/A | |||||||||
Light Emitting Diode (LED) Block Frequency | N/A | |||||||||
Light Emitting Diode (LED) Color | N/A | |||||||||
Approximate Weight | N/A | N/A 866 g | N/A | N/A | N/A 570 g | |||||
Approximate Net Weight | N/A | N/A 736 g | N/A | N/A | N/A 466 g | |||||
Weight | N/A 1 lb | N/A 1 lb | N/A 1 lb | N/A 0.5 lb | N/A 0.5 lb | |||||
Note | N/A |
N/A
|
N/A | N/A |
N/A
|
|||||
|