Safety Controllers
Safety
Unit of Measure
Items |
![]() SFC-R412-L 24 Volt (V) Direct Current (DC) Voltage and 4 Watt (W) Power Consumption Safety Controller List Price $180.95
|
![]() SFC-R412 24 Volt (V) Direct Current (DC) Voltage and 4 Watt (W) Power Consumption Safety Controller List Price $180.95
|
![]() SFC-R212-R230-L 24 Volt (V) Direct Current (DC) Voltage and 6 Watt (W) Power Consumption Safety Controller List Price $262.95
|
![]() SFC-R212-R230 24 Volt (V) Direct Current (DC) Voltage and 6 Watt (W) Power Consumption Safety Controller List Price $262.95
|
![]() SFC-R212-R23-L 24 Volt (V) Direct Current (DC) Voltage and 6 Watt (W) Power Consumption Safety Controller List Price $262.95
|
|||||
Description | N/A | |||||||||
Brands | N/A Autonics USA | |||||||||
Type | N/A Safety | |||||||||
Direct Current (DC) Voltage | N/A 24 V | |||||||||
Allowable Voltage Range | N/A 85 to 110 V | |||||||||
Power Consumption | N/A 4 W | N/A 4 W | N/A 6 W | N/A 6 W | N/A 6 W | |||||
Input Current (On) | N/A ≥ 5 mA | |||||||||
Direct Current (DC) Input Voltage (On) | N/A ≥ 11 V | |||||||||
Input Current (Off) | N/A ≤ 1 mA | |||||||||
Direct Current (DC) Input Voltage (Off) | N/A ≤ 5 V | |||||||||
Input Time | N/A ≥ 50 ms | |||||||||
Feedback Start Time (Manual) | N/A ≥ 100 ms | |||||||||
Cable Length | N/A ≤ 100 m | |||||||||
Cable Capacitance | N/A ≤ 10 nF | |||||||||
Cable Resistance | N/A ≤ 100 Ω | |||||||||
Safety Output | N/A Relay (A Contact) | |||||||||
Sub Output | N/A 1 x Positive Negative Positive (PNP) Transistor: X1 | |||||||||
Instantaneous | N/A 4 x | N/A 4 x | N/A 2 x | N/A 2 x | N/A 2 x | |||||
Off-Delay | N/A | N/A | N/A 2 × | N/A 2 × | N/A 2 × | |||||
Time Accuracy (±) | N/A | N/A | N/A ≤ 5 % | N/A ≤ 5 % | N/A ≤ 5 % | |||||
Direct Current (DC) Capacity | N/A 5 A | |||||||||
Alternating Current (AC) Capacity | N/A 5 A | |||||||||
Alternating Current (AC) Voltage Capacity | N/A 240 V | |||||||||
Direct Current (DC) Voltage Capacity | N/A 30 V | |||||||||
Mechanical Life Expectancy | N/A ≥ 10000000 Operations | |||||||||
Malfunction Life Expectancy | N/A ≥ 50000 Operations | N/A = 50000 Operations | N/A = 50000 Operations | N/A = 50000 Operations | N/A = 50000 Operations | |||||
Contact Resistance | N/A ≤ 100 mΩ | |||||||||
Inductive Load Switching | N/A IEC60947-5-1: AC-15 (230 V/2 A) | |||||||||
Conditional Short Circuit Current | N/A 100 A | |||||||||
Number of Connections | N/A | |||||||||
Number of Total Connections | N/A | |||||||||
Number of Layers | N/A | |||||||||
Safety Non Contact (SFN) Connections | N/A | |||||||||
Maximum Load Current | N/A 100 mA | |||||||||
Load Output Direct Current (DC) (Below 2-Point) | N/A | |||||||||
Load Output Direct Current (DC) (Over 3-Point) | N/A | |||||||||
Leakage Current | N/A ≤ 0.1 mA | |||||||||
Maximum Expansion Units Connections | N/A | |||||||||
International Standards | N/A European Standard (EN) International Organization for Standardization (ISO) 13849-1 (Category 4, PLe) Underwriter Laboratories (UL) Listed E249635 International Electrotechnical Commission (IEC)/European Standard (EN) 61508 (Safety Integrity Level (SIL)3) International Electrotechnical Commission (IEC)/European Standard (EN) 62061 (Safety Integrity Level (SIL) CL3) International Electrotechnical Commission (IEC)/European Standard (EN) 60947-5-1 | |||||||||
Approval | N/A European Conformity (CE) S-Mark Certification Technical Inspection Association (TUV NORD) Underwriter Laboratories (UL) Listed | |||||||||
Shipping Weight | N/A 160 g | N/A 160 g | N/A 150 g | N/A 150 g | N/A 150 g | |||||
Unit Weight | N/A 110 g | |||||||||
Weight | N/A 0.2 lb | |||||||||
|