Unit of Measure
Items
Safety Light Curtains

15 Meter (m) Sensing Distance and 25 Millimeter (mm) Optical Axis Pitch Safety Light Curtain
List Price $948.95

Safety Light Curtains

15 Meter (m) Sensing Distance and 25 Millimeter (mm) Optical Axis Pitch Safety Light Curtain
List Price $3,314.95

Safety Light Curtains

15 Meter (m) Sensing Distance and 25 Millimeter (mm) Optical Axis Pitch Safety Light Curtain
List Price $3,206.95

Safety Light Curtains

15 Meter (m) Sensing Distance and 25 Millimeter (mm) Optical Axis Pitch Safety Light Curtain
List Price $3,099.95

Safety Light Curtains

15 Meter (m) Sensing Distance and 25 Millimeter (mm) Optical Axis Pitch Safety Light Curtain
List Price $2,991.95
Description N/A Safety Light Curtains, Advanced type, Through-beam, 15 M Sensing distance, 9 pcs & 25 mm Optical ax. N/A Safety Light Curtains, Advanced type, Through-beam, 15 M Sensing distance, 75 pcs & 25 mm Optical a. N/A Safety Light Curtains, Advanced type, Through-beam, 15 M Sensing distance, 72 pcs & 25 mm Optical a. N/A Safety Light Curtains, Advanced type, Through-beam, 15 M Sensing distance, 69 pcs & 25 mm Optical axis pitch, 1,718 mm length, 24 VDC N/A Safety Light Curtains, Advanced type, Through-beam, 15 M Sensing distance, 66 pcs & 25 mm Optical axis pitch, 1,643 mm length, 24 VDC
Brands N/A Autonics USA
Sensing Type N/A Through-Beam
Light Source N/A Infrared Light Emitting Diode (LED) N/A Infrared Light Emitting Diode (LED) N/A Infrared Light Emitting Diode (LED) N/A N/A
Light Source Wavelength N/A 855 nm N/A 855 nm N/A 855 nm N/A N/A
Effective Aperture Angle (EAA) (±) N/A Within 2.5 º N/A N/A N/A N/A
Effective Aperture Angle (EAA) within (when the Sensing Distance is Greater than 3 Meter (m) for both Emitter and Receiver) (±) N/A N/A 2.5 º N/A 2.5 º N/A N/A
Sensing Distance N/A 15 m
Note for Sensing Distance N/A Short - Long Mode (Setting Switch or Atlightcurtain) N/A Short - Long Mode (Setting Switch or Atlightcurtain) N/A Short - Long Mode (Setting Switch or Atlightcurtain) N/A N/A
Short Mode N/A 0.2 to 8 m N/A 0.2 to 8 m N/A 0.2 to 8 m N/A N/A
Long Mode N/A 0.2 to 15 m N/A 0.2 to 15 m N/A 0.2 to 15 m N/A N/A
Detection Capability Diameter (Hand-Body) N/A 30 mm N/A 30 mm N/A 30 mm N/A N/A
Detection Capability Diameter (Finger) N/A
Detection Capability Diameter (Hand) N/A
Sensing Target N/A Opaque N/A Opaque N/A Opaque N/A N/A
Number of Optical Axes or Pieces N/A 9 N/A 75 N/A 72 N/A 69 N/A 66
Optical Axis Pitch N/A 25 mm
Maximum Series Connection Set N/A 4 N/A 4 N/A 4 N/A N/A
Series Connection Optical Axes N/A ≤ 400 N/A ≤ 400 N/A ≤ 400 N/A N/A
Direct Current (DC) Voltage N/A 24 V
Direct Current (DC) Voltage Tolerance (±) N/A 20 % N/A 20 % N/A 20 % N/A N/A
Maximum P to P Ripple Factor N/A ≤ 10 % N/A ≤ 10 % N/A ≤ 10 % N/A N/A
Current Consumption (Emitter) N/A ≤ 106 mA N/A ≤ 106 mA N/A ≤ 106 mA N/A N/A
Current Consumption (Receiver) N/A ≤ 181 mA N/A ≤ 181 mA N/A ≤ 181 mA N/A N/A
Negative Positive Negative (NPN) Open Collector Load Direct Current (DC) Voltage (Safety Related Output except for the Residual Voltage) N/A 24 V N/A 24 V N/A 24 V N/A N/A
Positive Negative Positive (PNP) Open Collector Load Direct Current (DC) Voltage (Safety Related Output except for the Residual Voltage) N/A 24 V N/A 24 V N/A 24 V N/A N/A
Negative Positive Negative (NPN) Open Collector Load Direct Current (DC) Voltage (Auxiliary Output 1 and 2) N/A ≤ 24 V N/A ≤ 24 V N/A ≤ 24 V N/A N/A
Positive Negative Positive (PNP) Open Collector Load Direct Current (DC) Voltage (Auxiliary Output 1 and 2) N/A ≤ 24 V N/A ≤ 24 V N/A ≤ 24 V N/A N/A
Negative Positive Negative (NPN) Open Collector Load Direct Current (DC) Voltage (Lamp Output 1 and 2) N/A ≤ 24 V N/A ≤ 24 V N/A ≤ 24 V N/A N/A
Positive Negative Positive (PNP) Open Collector Load Direct Current (DC) Voltage (Lamp Output 1 and 2) N/A ≤ 24 V N/A ≤ 24 V N/A ≤ 24 V N/A N/A
Protection Circuit N/A Output Short-circuit Over-current Protection Reverse Output Polarity Reverse Power Polarity N/A Output Short-circuit Over-current Protection Reverse Output Polarity Reverse Power Polarity N/A Output Short-circuit Over-current Protection Reverse Output Polarity Reverse Power Polarity N/A N/A
Safety-Related Functions N/A Blanking (Fixed Blanking and Floating Blanking) External Device Monitoring (EDM) Interlock (Reset Hold) Muting/Override Reduced Resolution N/A Blanking (Fixed Blanking and Floating Blanking) External Device Monitoring (EDM) Interlock (Reset Hold) Muting/Override Reduced Resolution N/A Blanking (Fixed Blanking and Floating Blanking) External Device Monitoring (EDM) Interlock (Reset Hold) Muting/Override Reduced Resolution N/A N/A
General Functions N/A Alarm for Reduction of Incident Light Level Mutual Interference Prevention Self-Test N/A Alarm for Reduction of Incident Light Level Mutual Interference Prevention Self-Test N/A Alarm for Reduction of Incident Light Level Mutual Interference Prevention Self-Test N/A N/A
Others Functions N/A Change of Sensing Distance External Test (Light Emission Stops), Auxiliary Output (AUX 1, 2), Lamp Output (LAMP1, 2) Switching to NPN or PNP N/A Change of Sensing Distance External Test (Light Emission Stops), Auxiliary Output (AUX 1, 2), Lamp Output (LAMP1, 2) Switching to NPN or PNP N/A Change of Sensing Distance External Test (Light Emission Stops), Auxiliary Output (AUX 1, 2), Lamp Output (LAMP1, 2) Switching to NPN or PNP N/A N/A
Synchronization Type N/A Timing Method by Synchronous Line N/A Timing Method by Synchronous Line N/A Timing Method by Synchronous Line N/A N/A
Insulation Resistance at 500 Volt (V) Direct Current (DC) Megger Voltage N/A 20 MΩ N/A 20 MΩ N/A 20 MΩ N/A N/A
Noise Immunity N/A The Square Wave Noise (Pulse Width: 1㎲) by the noise simulator ± 240VDC N/A The Square Wave Noise (Pulse Width: 1㎲) by the noise simulator ± 240VDC N/A The Square Wave Noise (Pulse Width: 1㎲) by the noise simulator ± 240VDC N/A N/A
Dielectric Strength Alternating Current (AC) Voltage Between Power off Terminals (At 50/60 Hertz (Hz) Frequency for 1 Minute) N/A 1000 V N/A 1000 V N/A 1000 V N/A N/A
Vibration N/A 0.7 mm amplitude at frequency of 10 to 55Hz (for 1 min), 20 sweeps in each X, Y, Z direction N/A 0.7 mm amplitude at frequency of 10 to 55Hz (for 1 min), 20 sweeps in each X, Y, Z direction N/A 0.7 mm amplitude at frequency of 10 to 55Hz (for 1 min), 20 sweeps in each X, Y, Z direction N/A N/A
Approximate Shock in Each X,Y,Z Direction for 1000 Times N/A 100 m/s²10 g N/A 100 m/s²10 g N/A 100 m/s²10 g N/A N/A
Pulse Width in Each X, Y, Z Direction for 1000 Times N/A 16 ms N/A 16 ms N/A 16 ms N/A N/A
Maximum Environment Ambient Received Illumination (Sunlight) N/A 10000 lx N/A 10000 lx N/A 10000 lx N/A N/A
Maximum Environment Ambient Received Illumination (Incandescent Lamp) N/A 3000 lx N/A 3000 lx N/A 3000 lx N/A N/A
Ambient Temperature (Non-Freezing or Non-Condensation) N/A -10 to 55 ºC N/A -10 to 55 ºC N/A -10 to 55 ºC N/A N/A
Ambient Storage Temperature (Non-Freezing or Non-Condensation) N/A -20 to 70 ºC N/A -20 to 70 ºC N/A -20 to 70 ºC N/A N/A
Environment Ambient Relative Humidity (RH) (Non-Freezing or Non-Condensation) N/A 35 to 85 % N/A 35 to 85 % N/A 35 to 85 % N/A N/A
Environment Ambient Storage Relative Humidity (RH) (Non-Freezing or Non-Condensation) N/A 35 to 95 % N/A 35 to 95 % N/A 35 to 95 % N/A N/A
Protection Structure N/A Ingress Protection (IP) 65 (International Electrotechnical Commission (IEC) Standard) Ingress Protection (IP) 67 (International Electrotechnical Commission (IEC) Standard) N/A Ingress Protection (IP) 65 (International Electrotechnical Commission (IEC) Standard) Ingress Protection (IP) 67 (International Electrotechnical Commission (IEC) Standard) N/A Ingress Protection (IP) 65 (International Electrotechnical Commission (IEC) Standard) Ingress Protection (IP) 67 (International Electrotechnical Commission (IEC) Standard) N/A N/A
Case Material N/A Aluminum N/A Aluminum N/A Aluminum N/A N/A
Front Cover Material N/A Polymethyl Methacrylate N/A Polymethyl Methacrylate N/A Polymethyl Methacrylate N/A N/A
Sensing Part Material N/A Polymethyl Methacrylate N/A Polymethyl Methacrylate N/A Polymethyl Methacrylate N/A N/A
End Cap Material N/A Polycarbonates (PC) N/A Polycarbonates (PC) N/A Polycarbonates (PC) N/A N/A
Cable Material N/A Polyurethane (PUR) N/A Polyurethane (PUR) N/A Polyurethane (PUR) N/A N/A
Approval N/A European Conformities (CE) Technical Inspection Association (TUV) Underwriters Laboratory for Canada and United States (cULus) N/A European Conformities (CE) Technical Inspection Association (TUV) Underwriters Laboratory for Canada and United States (cULus) N/A European Conformities (CE) Technical Inspection Association (TUV) Underwriters Laboratory for Canada and United States (cULus) N/A N/A
International Standards N/A Canadian Standards Association (CSA) C22.2 No. 14 International Electrotechnical Commission (IEC)/European Standards (EN) 61496-1 (Type 4, ESPE) International Electrotechnical Commission (IEC)/European Standards (EN) 61496-2 (Type 4, AOPDs) International Electrotechnical Commission (IEC)/European Standards (EN) 61508-1~-7 (SIL 3) International Electrotechnical Commission (IEC)/European Standards (EN) 62061 (Safety Integrity Level, Claim Limit (CIL CL 3)) International Organization for Standardization (ISO) 13849-1 (PL e, Cat. 4) International Organization for Standardization (ISO) 13849-2 (PLe, Cat. 4) Underwriters' Laboratories (UL) 508 Underwriters' Laboratories (UL) 61496-1 (Type 4, ESPE) Underwriters' Laboratories (UL) 61496-2 (Type 4, AOPDs) N/A Canadian Standards Association (CSA) C22.2 No. 14 International Electrotechnical Commission (IEC)/European Standards (EN) 61496-1 (Type 4, ESPE) International Electrotechnical Commission (IEC)/European Standards (EN) 61496-2 (Type 4, AOPDs) International Electrotechnical Commission (IEC)/European Standards (EN) 61508-1~-7 (SIL 3) International Electrotechnical Commission (IEC)/European Standards (EN) 62061 (Safety Integrity Level, Claim Limit (CIL CL 3)) International Organization for Standardization (ISO) 13849-1 (PL e, Cat. 4) International Organization for Standardization (ISO) 13849-2 (PLe, Cat. 4) Underwriters' Laboratories (UL) 508 Underwriters' Laboratories (UL) 61496-1 (Type 4, ESPE) Underwriters' Laboratories (UL) 61496-2 (Type 4, AOPDs) N/A Canadian Standards Association (CSA) C22.2 No. 14 International Electrotechnical Commission (IEC)/European Standards (EN) 61496-1 (Type 4, ESPE) International Electrotechnical Commission (IEC)/European Standards (EN) 61496-2 (Type 4, AOPDs) International Electrotechnical Commission (IEC)/European Standards (EN) 61508-1~-7 (SIL 3) International Electrotechnical Commission (IEC)/European Standards (EN) 62061 (Safety Integrity Level, Claim Limit (CIL CL 3)) International Organization for Standardization (ISO) 13849-1 (PL e, Cat. 4) International Organization for Standardization (ISO) 13849-2 (PLe, Cat. 4) Underwriters' Laboratories (UL) 508 Underwriters' Laboratories (UL) 61496-1 (Type 4, ESPE) Underwriters' Laboratories (UL) 61496-2 (Type 4, AOPDs) N/A N/A
Weight N/A 0.2 lb
Applications N/A Safety
Note N/A
  • Current consumption, Response time: It may differ depending on the models. For more information, see the "SFL/SFLA User Manual."
  • Load voltage of Safety related output: The values of load voltage were drawn with PNP output, and in case of NPN output, apply these in reverse.
  • Load current of Safety related output: Be sure that the load current should be greater than 6 mA
  • Residual voltage of Safety related output: The residual voltage was drawn with 300 mA of load current.
  • Auxiliary output, Lamp output: It is the non-safety output. Do not use it for safety purposes.
N/A
  • Current consumption, Response time: It may differ depending on the models. For more information, see the "SFL/SFLA User Manual."
  • Load voltage of Safety related output: The values of load voltage were drawn with PNP output, and in case of NPN output, apply these in reverse.
  • Load current of Safety related output: Be sure that the load current should be greater than 6 mA
  • Residual voltage of Safety related output: The residual voltage was drawn with 300 mA of load current.
  • Auxiliary output, Lamp output: It is the non-safety output. Do not use it for safety purposes.
N/A N/A N/A