Single Display Modular Temperature Controller, 2 Relay Output, Alarm Output, CT Input, RS485, 10…
Unit of Measure

Specifications

Brands

N/A Autonics USA

Alternating Current (AC) Voltage

N/A 100 to 240 V

Frequency

N/A 50 Hz60 Hz

Control Method

N/A On/Off Control P PD PI PID Control

Sampling Cycle

N/A 50 ms100 ms250 ms

Approval

N/A European Conformity (CE)

Environment Ambient Temperature

N/A -10 to 50 ºC

Environment Storage Temperature

N/A -20 to 60 ºC

Environment Ambient Relative Humidity (RH)

N/A 35 to 85 %

Environment Storage Relative Humidity (RH)

N/A 35 to 85 %

Display Method

N/A 4-Digit 7-Segment (Red)

Thermocouple Input Specification

N/A J(IC) K(CA) L(IC) R(PR) S(PR) T(CC)

Resistance Temperature Detector (RTD) Input Specification

N/A Cu50Ω DPt100Ω Nickel120Ω (Permissible Line Resistance Maximum 5Ω)

Alarm Output Hysteresis

N/A Alarm output: 1 to 100ºC/ºF (0.1 to 50.0ºC/ºF)

Proportional Band

N/A 0.1 to 999.9ºC

Integral Time Range

N/A 0 to 9999 s

Derivative Time

N/A 0 to 9999 s

Control Period

N/A 0.5 to 120.0 s

Insulation Resistance

N/A 100MΩ or More (500VDC Megger Basis)

Noise Immunity

N/A Square Shaped Noise by Noise Simulator (Pulse Width 1µs) ±2kV R-phase, S-phase

Dielectric Strength

N/A 3000VAC 50/60Hz for 1 min (Between the Power Part and the Case)

Vibration

N/A 0.75mm Amplitude at Frequency of 5 to 55Hz (for 1 min) in Each X, Y, Z Direction for 2 Hours

Power Consumption

N/A 8

Insulation Type

N/A Double Insulation or Reinforced Insulation (Dielectric Strength Between Measuring the Power Part and the Case : 3kV)

Display Accuracy Resistance Temperature Detector (RTD)

N/A
  • At room temperature (23ºC ±5ºC): (PV ±0.3% or ±1ºC, select the higher one) ±1-digit
  • Out of room temperature ranges: (PV ±+H400.5% or ±2ºC, select the higher one) ±1-digit

Display Accuracy Thermocouple

N/A
  • At room temperature (23ºC ±5ºC): (PV ±0.3% or ±1ºC, select the higher one) ±1-digit
  • Out of room temperature ranges: (PV ±+H400.5% or ±2ºC, select the higher one) ±1-digit

CT Input Display Accuracy

N/A ±5% F.S. ±1-Digit

Hysteresis Control Output

N/A Control output: 1 to 100ºC/ºF (0.1 to 100.0ºC/ºF), Alarm output: 1 to 100ºC/ºF (0.1 to 50.0ºC/ºF)

Allowable Rated Voltage Range

N/A 90 to 110 %

CT Input Type

N/A 0.0 to 50.0A (Primary Current Measurement Range) CT Ratio=1/1000

Control Output Relay

N/A 250VAC 3A 1a

Option Output Alarm

N/A AL1, AL2: 250VAC 3A 1a

Option Output Transmission

N/A Direct Current (DC) 4 to 20mA (Load Resistance: Maximum 500Ω)

Communication Option Output

N/A RS485 Communication Output (Modbus RTU/ASCII Method)

Mechanical Relay Life Cycle

N/A OUT1/2, AL1/2: Minimum 5000000 Operations

Electrical Relay Life Cycle

N/A OUT1/2, AL1/2: Minimum 100000 (Resistance Load: 250VAC, 5A)

Memory Protection

N/A Approximate 10 years (Non-volatile Semiconductor Memory Type)

Shipping Weight

N/A 123.5 g

Unit Weight

N/A 194.5 g

Weight

N/A 0.2 lb