Print Back
24 to 240 Volt (V) Alternating Current (AC) Voltage and -10 to 55 Degree Celsius (ºC) Environment Ambient Temperature Timer (LE3SA)
Unit of Measure
Items 24 to 240 Volt (V) Alternating Current (AC) Voltage and -10 to 55 Degree Celsius (ºC) Environment Ambient Temperature Timer (LE3SA)
LE3SA
24 to 240 Volt (V) Alternating Current (AC) Voltage and -10 to 55 Degree Celsius (ºC) Environment Ambient Temperature Timer
List Price $92.95
24 to 240 Volt (V) Alternating Current (AC) Voltage and -10 to 55 Degree Celsius (ºC) Environment Ambient Temperature Timer (LE3S)
LE3S
24 to 240 Volt (V) Alternating Current (AC) Voltage and -10 to 55 Degree Celsius (ºC) Environment Ambient Temperature Timer
List Price $92.95
100 to 240 Volt (V) Alternating Current (AC) Voltage and -10 to 55 Degree Celsius (ºC) Environment Ambient Temperature Timer (ATE8-41)
ATE8-41
100 to 240 Volt (V) Alternating Current (AC) Voltage and -10 to 55 Degree Celsius (ºC) Environment Ambient Temperature Timer
List Price $21.95
-10 to 55 Degree Celsius (ºC) Environment Ambient Temperature and -10 to 55 Degree Celsius (ºC) Environment Ambient Temperature Counter (LE8N-BV-L)
LE8N-BV-L
-10 to 55 Degree Celsius (ºC) Environment Ambient Temperature and -10 to 55 Degree Celsius (ºC) Environment Ambient Temperature Timer
List Price $69.95
-10 to 55 Degree Celsius (ºC) Environment Ambient Temperature and -10 to 55 Degree Celsius (ºC) Environment Ambient Temperature Counter (LE8N-BV)
LE8N-BV
-10 to 55 Degree Celsius (ºC) Environment Ambient Temperature and -10 to 55 Degree Celsius (ºC) Environment Ambient Temperature Timer
List Price $63.95
Description N/A Timer, Digital, 1/16 DIN, On-Delay, Multi-Range, DPDT, 24-240 VAC (socket required) N/A Timer, Digital,1/16 DIN,10 Mode, Multi-Range, SPDT Out, 24-240 VAC/DC (socket required) N/A Timer, Analog, 1 Sec/ 10 Sec/ 1 Min/ 10 Min/ 1 Hour, Time limit 1C + Instantaneous 1a, 8-Pin N/A Hour Meter, 8 digits LCD, 1/32 DIN, Built-in Battery power, Selectable front reset key, Voltage N/A Hour Meter, 8 digits LCD, 1/32 DIN, Built-in Battery power, Selectable front reset key, Voltage
Brands N/A Autonics USA
Display Method N/A 3-Digit 7-Segment Liquid Crystal Display (LCD) N/A 3-Digit 7-Segment Liquid Crystal Display (LCD) N/A N/A 8-Digit 7-Segment Liquid Crystal Display (LCD) N/A 8-Digit 7-Segment Liquid Crystal Display (LCD)
Operation Method N/A Count Down Count Up N/A Count Down Count Up N/A Time Setting N/A Count Up N/A Count Up
Output Operation N/A Power On Delay N/A Flicker Integration Time Interval Delay Off Delay On Delay One-Shot Out Flicker On-Off Delay N/A Power On Delay N/A N/A
Time Operation N/A Power On Delay N/A Signal On Start N/A Power On Start N/A Power On Start N/A Power On Start
Terminal N/A 8-Pin Plug N/A 8-Pin Plug N/A 8-Pin Plug N/A Terminal Block N/A Terminal Block
Alternating Current (AC) Voltage N/A 24 to 240 V N/A 24 to 240 V N/A 100 to 240 V N/A N/A
Direct Current (DC) Voltage N/A 24 to 240 V N/A 24 to 240 V N/A 24 to 240 V N/A N/A
Frequency N/A N/A N/A 50 Hz60 Hz N/A N/A
Power Supply N/A N/A N/A N/A Built-in battery (over 10 years) N/A Built-in battery (over 10 years)
Setting Range N/A 0 Hour 01 Minute to 9 Hour 59 Minute 0 Minute 01 Second to 9 Minute 59 Second 0.01 Second to 9.99 Second 0.1 Hour to 99.9 Hour 0.1 Minute to 99.9 Minute 0.1 Second to 99.9 Second 1 Hour to 999 Hour 1 Minute to 999 Minute 1 Second to 999 Second 10 Hour to 9990 Hour N/A 0 Hour 01 Minute to 9 Hour 59 Minute 0 Minute 01 Second to 9 Minute 59 Second 0.01 Second to 9.99 Second 0.1 Hour to 99.9 Hour 0.1 Minute to 99.9 Minute 0.1 Second to 99.9 Second 1 Hour to 999 Hour 1 Minute to 999 Minute 1 Second to 999 Second 10 Hour to 9990 Hour N/A 0.1 to 1 Hour 0.1 to 1 Minute 0.1 to 1 Second 1 to 10 Minute 1 to 10 Second N/A 0.01 Second to 9999 Hour 59 Minute 59 Second 0.1 Hour 0.1 Hour to 9999 day 23.9 Hour 0.1 Minute to 9999 Hour 59.9 Minute 0.1 Minute to 99999 Hour 59.9 Minute 1 Minute to 9999 day 23 Hour 59 Minute 1 Minute to 99999 Hour 59 Minute 1 Minute to 999999 Hour 59 Minute 1 Second to 99999999 Second N/A 0.01 Second to 9999 Hour 59 Minute 59 Second 0.1 Hour 0.1 Hour to 9999 day 23.9 Hour 0.1 Minute to 9999 Hour 59.9 Minute 0.1 Minute to 99999 Hour 59.9 Minute 1 Minute to 9999 day 23 Hour 59 Minute 1 Minute to 99999 Hour 59 Minute 1 Minute to 999999 Hour 59 Minute 1 Second to 99999999 Second
Input Method Signal N/A N/A N/A N/A Voltage Input (Positive Negative Positive (PNP)) N/A Voltage Input (Positive Negative Positive (PNP))
Input Method Reset N/A N/A N/A N/A Voltage Input (Positive Negative Positive (PNP)) N/A Voltage Input (Positive Negative Positive (PNP))
Control Output N/A N/A N/A Instantaneous Single Pole Single Throw (SPST) (1A): 1 Time-Limit Single Pole Double Throw (SPDT) (1C): 1 N/A Indicator N/A Indicator
Backlight N/A N/A N/A N/A Backlight Function N/A
Protection Structure N/A N/A N/A Ingress Protection (IP) 40 (Front Panel) N/A Ingress Protection (IP) 66 (Front Panel) N/A Ingress Protection (IP) 66 (Front Panel)
Control Output Relay N/A Time-Limit Single Pole Double Throw (SPDT) (1C): 2 N/A Time-Limit Single Pole Double Throw (SPDT) (1C): 1 N/A N/A N/A
Time/Month Deviation (±) N/A
Time Deviation N/A
Approval N/A European Conformity (CE) Underwriters Laboratory for Canada and United States (cULus) Listed N/A European Conformity (CE) Underwriters Laboratory Recognized Component (cRUus) N/A European Conformity (CE) Underwriters Laboratory for Canada and United States (cULus) Listed N/A European Conformity (CE) Underwriters Laboratory Recognized Component (cRUus) N/A European Conformity (CE) Underwriters Laboratory Recognized Component (cRUus)
Approximate Minimum Signal Width for Start N/A N/A 20 ms N/A N/A 20 ms N/A 20 ms
Approximate Minimum Signal Width for Inhibit N/A N/A 20 ms N/A N/A 20 ms N/A 20 ms
Approximate Minimum Signal Width for Reset N/A N/A 20 ms N/A N/A 20 ms N/A 20 ms
External Set Switch N/A N/A N/A N/A SW1 SW2 SW3 N/A SW1 SW2 SW3
Environment Ambient Temperature N/A -10 to 55 ºC
Environment Storage Temperature N/A -25 to 65 ºC
Environment Ambient Relative Humidity (RH) N/A 35 to 85 %
Type N/A N/A N/A N/A Hour Meter Liquid Crystal Display (LCD) N/A Hour Meter Liquid Crystal Display (LCD)
Width N/A
Height N/A
Memory Protection N/A
Signal Input Method N/A N/A No-Voltage Input (Negative Positive Negative (NPN)) N/A N/A N/A
Digit N/A
Input Type N/A
Number of Setting Steps N/A
Contact Type N/A
Control Time Setting Range N/A
Approximate Net Weight N/A N/A N/A 75 g N/A 50 g N/A 50 g
Approximate Weight N/A 105 g N/A 100 g N/A 122.2 g N/A 96 g N/A 96 g
Weight N/A 0.2 lb
Function N/A
Accessories N/A Bracket N/A Bracket N/A N/A Mounting Bracket Rubber Waterproof Ring N/A Mounting Bracket Rubber Waterproof Ring
Note N/A N/A
  • Sockets (PG-08, PS-08(N), PS-M8) are sold separately.
  • The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.
  • The weight includes packaging. The weight in parenthesis is for unit only.
N/A N/A
  • SW1 is the front panel RESET key enable/disable set switch.
  • SW2 is the time range set switch.
  • SW3 is available to select time specification TS1, TS2, or TS3.
  • No-voltage input, voltage input: between terminals and the case,
  • Free voltage input: between the free voltage input terminal and the RESET input terminal, between terminals and the case
  • The weight includes packaging. The weight in parenthesis is for unit only.
  • The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.
N/A
  • SW1 is the front panel RESET key enable/disable set switch.
  • SW2 is the time range set switch.
  • SW3 is available to select time specification TS1, TS2, or TS3.
  • No-voltage input, voltage input: between terminals and the case,
  • Free voltage input: between the free voltage input terminal and the RESET input terminal, between terminals and the case
  • The weight includes packaging. The weight in parenthesis is for unit only.
  • The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.