Brands |
N/A Autonics USA |
Direct Current (DC) Voltage |
N/A 24 V |
Input Type Analog Voltage |
N/A 0 to 100mVDC 0 to 10VDC 0 to 5VDC 1 to 5VDC |
Input Type Analog Current |
N/A 0 to 20mA 4 to 20mA |
Control Method |
N/A On/Off Control P PD PI PID Control |
Sampling Cycle |
N/A 50 ms |
Note for Sampling Cycle |
N/A (2-CH or 4-CH Synchronous Sampling) |
Protection Structure |
N/A Ingress Protection (IP) 20 (International Electrotechnical Commission (IEC) Standard) |
Approval |
N/A Canadian and US Standards by Underwriters' Laboratories (CURUS) European Conformity (CE) Korea Certification (KC) |
Environment Ambient Temperature |
N/A -10 to 50 ºC |
Environment Storage Temperature |
N/A -20 to 60 ºC |
Environment Ambient Relative Humidity (RH) |
N/A 35 to 85 % |
Environment Storage Relative Humidity (RH) |
N/A 35 to 85 % |
Display Method |
N/A None-parameter Setting and Monitoring is Available at External Devices (PC, PLC, etc.) |
Thermocouple Input Specification |
N/A B(PR) C(TT) E(CR) G(TT) J(IC) K(CA) L(IC) N(NN) Platinel II R(PR) S(PR) T(CC) U(CC) |
Resistance Temperature Detector (RTD) Input Specification |
N/A Cu100Ω Cu50Ω DPt100Ω DPt50Ω JPt100Ω Nickel 120Ω 3-wire type(permissible line resistance max. 5Ω) |
Proportional Band |
N/A RTD/Thermocouples: 1 to 999℃/ºF (0.1 to 999.9℃/ºF), analog: 0.1 to 999.9 digit |
Integral Time Range |
N/A 0 to 9999 s |
Derivative Time |
N/A 0 to 9999 s |
Relay Output Control Period |
N/A 0.1 to 120.0 s |
SSR Output Control Period |
N/A 1.0 to 120.0 s |
Insulation Resistance |
N/A 100MΩ (at 500VDC Megger) |
Noise Immunity |
N/A ±0.5kV the Square Wave Noise (Pulse Width: 1µs) By the Noise Simulator |
Dielectric Strength |
N/A 1000VAC 50/60Hz for 1 min (Between Input Terminals and Power Terminals) |
Vibration |
N/A 0.75mm Amplitude at Frequency of 5 to 55Hz (for 1 min) in Each X, Y, Z Direction for 2 Hours |
Power Consumption |
N/A 8 |
Insulation Type |
N/A Double Insulation or Reinforced Insulation (Dielectric Strength Between the Measuring Input Part and the Power Part: 1kv) |
Hysteresis (Adjustable Sensitivity) |
N/A RTD/Thermocouples: 1 to 100ºC/ºF (0.1 to 100.0ºC/ºF), Analog: 1 to 100 Digit |
Manual Reset |
N/A 0 to 100%( 0.0 to 100.0%) |
Allowable Rated Voltage Range |
N/A 90 to 110 % |
Control Output Relay |
N/A 250VAC, 3A, 1a |
Option Output Alarm |
N/A 250VAC, 3A, 1a |
Mechanical Relay Life Cycle |
N/A Minimum 10000000 Operations |
Electrical Relay Life Cycle |
N/A Minimum 100000 Operations (250VAC, 3A Resistance Load) |
Memory Protection |
N/A Approximate 10 Years(Non-volatile Semiconductor Memory Type) |
Maximum SSR Control Direct Current (DC) Voltage Output |
N/A 12 V |
SSR Control Direct Current (DC) Voltage Tolerance |
N/A ±3 V |
SSR Control Current Output |
N/A 20 mA |
Current Control Output |
N/A Selectable Direct Current (DC) 4 to 20mA or Direct Current (DC) 0 to 20mA (Load Resistance Maximum 500Ω) |
Number of Input Channels |
N/A 2-Channel |
Thermocouple Measurement Accuracy |
N/A
|
RTD Measurement Accuracy |
N/A
|
Analog Measurement Accuracy |
N/A
|
CT Input Option |
N/A 0.0-50.0A (Primary Current Measurement Range), CT Ratio=1/1000, Measured Accuracy: ±5% F.S. ±1-digit |
Communication Terminal |
N/A RS485 Communication Output (Modbus RTU) |
PC Loader Communication |
N/A TTL |
Option Digital Inputs |
N/A
Connect input: ON - max. 1kΩ, OFF - min. 100kΩ Solid-state input: ON - max. residual voltage 0.9V, OFF - max. leakage current 0.5mA Outflow current: approx. 0.3mA per input |
Shipping Weight |
N/A 172.6 g |
Unit Weight |
N/A 245.7 g |
Weight |
N/A 0.2 lb |
Accessories |
N/A Expansion Connector: 1 Module Lock Connector: 2 |
Note |
N/A
Measured accuracy: At room temperature (23?±5?)
Environment resistance is rated at no freezing or condensation. Since the expansion module is not supplied with power/comm. terminal. Order it with the basic module. |