Print Back
Unit of Measure

Specifications

Brands

N/A Autonics USA

Approval

N/A European Conformities (CE) Underwriters Laboratory for Canada and United States (cULus)

Operation Method

N/A Bipolar Constant Current Pentagon Drive

Applied Motor

N/A 5-Phase Stepper Motor

Resolution

N/A Full Step (1-division) Half Step (2-division) Micro Step (4, 5, 8, 10, 16, 20, 25, 40, 50, 80, 100, 125, 200, 250-division)

Number of Axes

N/A 1

Maximum Run Phase Current

N/A 1.4 A

Output

N/A Alarm

Alternating Current (AC) Voltage

N/A 100 to 220 V

Frequency

N/A 50 Hz60 Hz

Minimum Pulse Width (Clockwise(CW))

N/A 1 µs

Minimum Pulse Width (Counter Clockwise(CCW))

N/A 1 µs

Minimum Pulse Width (Hold Off)

N/A 1 ms

Duty Rate (Clockwise(CW))

N/A 50 %

Duty Rate (Coubter Clockwise(CCW))

N/A 50 %

Below Rising and Falling Time (Clockwise(CW))

N/A 130 ns

Below Rising and Falling Time (Counter Clockwise(CCW))

N/A 130 ns

Direct Current (DC) Input Voltage (High)

N/A 4 to 8 V

Direct Current (DC) Input Voltage (Low)

N/A 0 to 0.5 V

Pulse Input Current (Clockwise(CW))

N/A 7.5 to 14 mA

Pulse Input Current (Counter Clockwise(CCW))

N/A 7.5 to 14 mA

Pulse Input Current (Hold Off)

N/A 10 to 16 mA

Maximum Input Pulse Frequency (Clockwise(CW))

N/A 500 kHz

Maximum Input Pulse Frequency (Counter Clockwise(CCW))

N/A 500 kHz

Environment Ambient Temperature

N/A 0 to 50 ºC

Environment Ambient Storage Temperature

N/A -10 to 60 ºC

Environment Ambient Relative Humidity (RH)

N/A 35 to 85 %

Environment Ambient Storage Relative Humidity (RH)

N/A 35 to 85 %

Shipping Weight

N/A 820 g

Unit Weight

N/A 660 g

Maximum Current Consumption

N/A 3 A

Weight

N/A 1.98 lb