Brands |
N/A Autonics USA |
Applied Motor |
N/A 2-Phase |
Driver Alternating Current (AC) Voltage Power Supply |
N/A 200 to 240 V |
Frequency of Driver Power Supply |
N/A 50 Hz60 Hz |
Maximum Driver Run Current Per Phase |
N/A 2 A |
Driver Protection Structure |
N/A Ingress Protection (IP) 20 |
Driver Applied Motor |
N/A 2-phase closed loop stepper motor |
Frame Size |
N/A 60 |
Driver Environment Ambient Temperature |
N/A 0 to 50 ºC |
Driver Environment Storage Temperature |
N/A -10 to 60 ºC |
Driver Environment Ambient Relative Humidity (RH) |
N/A 35 to 85 % |
Driver Environment Storage Relative Humidity (RH) |
N/A 10 to 90 % |
Driver Approval |
N/A European Conformities (CE) Restriction of Hazardous Substances (RoHS) |
Motor Environment Ambient Relative Humidity (RH) |
N/A 20 to 85 % |
Motor Environment Storage Relative Humidity (RH) |
N/A 15 to 90 % |
Motor Approximate Weight |
N/A 1.75 kg1.90 kg |
Motor Environment Ambient Temperature |
N/A 0 to 40 ºC |
Motor Environment Storage Temperature |
N/A -20 to 70 ºC |
Driver Approximate Weight |
N/A 780 g1,020 g |
Motor Maximum Holding Torque |
N/A 22.43 N.m |
Motor Rotor Moment of Inertia |
N/A 490 g/cm² |
Motor Rated Current Per Phase |
N/A 2 A |
Motor Winding Resistance |
N/A 2.4 O |
Motor Basic Step Angle [Full/Half] |
N/A 0.9 º1.8 º |
Motor Operation Method |
N/A Bipolar constant current Drive |
Motor Protection Structure |
N/A Ingress Protection (IP) 30 |
Motor Resolution |
N/A 10,000PPR (2,500PPR x 4-multiply) |
Motor Output Phase |
N/A A B C |
Motor Maximum Response Frequency |
N/A 300 kHz |
Motor Approval |
N/A European Conformities (CE) |
Driver Operation Method |
N/A Bipolar constant current Drive |
Driver Output |
N/A B C) In-Position, Alarm Out, Encoder signal (A |
Inductance Measure Per Phase |
N/A 8.5 |